154
P3.88
Command pulse frequency sampling time for analog
output
Default value
3
Setting range
0
:
62.5 [ μs ]
1
:
125 [ μs ]
2
:
250 [ μs ]
3
:
500 [ μs ]
4
:
1 [ ms ]
5
:
2 [ ms ]
6
:
4 [ ms ]
7
:
8 [ ms ]
Specify the command pulse frequency sampling time for analog output.
The sampling time is for the analog output function. No effect is caused to the control even if the value is
changed.
P3.89
Feedback speed sampling time for analog output
Default value
1
Setting range
0
:
62.5 [ μs ]
1
:
125 [ μs ]
2
:
250 [ μs ]
3
:
500 [ μs ]
4
:
1 [ ms ]
5
:
2 [ ms ]
6
:
4 [ ms ]
7
:
8 [ ms ]
Specify the feedback speed sampling time for analog output.
The sampling time is for the analog output function. No effect is caused to the control even if the value is
changed.
*P3.90
Servo motor model setting
Default value
00
Setting range
00
:
No setting
01
:
SCH060201C-H
50
:
SCH060201C-T
02
:
SCH060401C-H
51
:
SCH060401C-T
05
:
SCH080751C-H
52
:
SCH080751C-T
05
:
SCH080731B-H
13
:
SCH080102E-H
18
:
SCH110122C-H
18
:
SCH110152C-H
17
:
SCH110122B-H
22
:
SCH110182C-H
13
:
SCH130102E-H
18
:
SCH130132E-H
18
:
SCH130152E-H
22
:
SCH130202E-H
11
:
SCH130102A-H
17
:
SCH130152H-H
27
:
SCH130262E-H
21
:
SCH130232H-H
27
:
SCH130382E-H
31
:
SCH180202H-A
32
:
SCH180302H-A
33
:
SCH180452H-A
90
:
SCH180252H-H
92
:
SCH180302H-H
95
:
SCH180432H-H
97
:
SCH180552H-H
98
:
SCH180752H-H
Specify according to the servo motor connected.