5.Parameter
[Parameter setting value【system parameter】]
5−28
■
System parameter
Page Description
Main Power, Input Type
Selects the input mode for power supplied to the main
circuit power supply.
Setting range varies depending on the hardware type.
00
Setting value
Description
00
:
_AC_3-phase
3
phase
AC
power is supplied to the
main circuit.
01
:
_AC_Single-phase
Single phase
AC
power is supplied to
the main circuit.
Motor Encoder Type
Motor encoder type in use is selected.
Setting range varies depending on the hardware type.
01
Setting value
Description
00
:
_Inclemental_ENC Incremental
Encoder
01
:
_Absolute_ENC Absolute
Encoder
Incremental Encoder, Function Setting
Incremental encoder type is selected when an incremental
encoder is used for the motor encoder.
Setting range varies depending on the hardware type.
02
Setting value
Description
00
:
_Stanndard
Wiring-Save Incremental Encoder [Standard
(4-Pairs)]
01
:
_7Pairs_INC-E Incremental
Encoder with CS Signal. [7-Pairs]
Incremental Encoder, Resolution Setting
Pulse number per motor shaft rotation is set when an
incremental encoder is used for the motor encoder.
03
Setting range
Unit
Standard
value
500
〜
65535 P/R
―
Absolute Encoder, Function Setting
Absolute encoder type is selected when an absolute encoder
is used for the motor encoder.
Setting range varies depending on the hardware type.
Can only be selected when 01:_Absolute_ENC is selected at
Page
01(
motor encoder type
)
.
04
Setting Description
04
:
_PA035C-2.5MH_Manu
PA035, Asynchronous, 2.5Mbps, Half Duplex (Manual Setting)
05
:
_PA035C-4MH_Manu
PA035, Asynchronous, 4Mbps, Half Duplex (Manual Setting)
06
:
_RA062C-2.5MH_Manu
RA062, Asynchronous, 2.5Mbps, Half Duplex (Manual Setting)
07
:
_RA062C-4MH_Manu
RA062, Asynchronous, 4Mbps, Half Duplex (Manual Setting)
80
:
_RA062M-1MF
RA062, Manchester, 1Mbps, Full Duplex
81
:
_RA062M-2MF
RA062, Manchester, 2Mbps, Full Duplex
82
:
_ABS-RII-1M ABS-R
Ⅱ
1Mbps
83
:
_ABS-RII-2M ABS-R
Ⅱ
2Mbps
84
:
_ABS-E
ABS-E, 1Mbps (Absolute Encoder with Incremental Signal)
Absolute Encoder, Resolution Setting
Divisions per motor shaft rotation are set when absolute
encoder is used for the motor encoder.
Can only be selected when 01:_Absolute_ENC is selected
at Page
01(
motor encoder type
)
.
05
Setting Description
00
:
_2048_FMT 2048
divisions
01
:
_4096_FMT 4096
divisions
02
:
_8192_FMT 8192
divisions
03
:
_16384_FMT 16384
divisions
04
:
_32768_FMT 32768
divisions
05
:
_65536_FMT 65536
divisions
06
:
_131072_FMT 131072
divisions
07
:
_262144_FMT 262144
divisions
08
:
_524288_FMT 524288
divisions
09
:
_1048576_FMT 1048576
divisions
0A
:
_2097152_FMT 2097152
divisions
Summary of Contents for Q1AA04003D
Page 3: ...TYPE S M0006890C Analogue Pulse Input Type Instruction Manual For Rotary Motor E N G L I S H ...
Page 238: ...Materials Dimension RS1 10 Materials 27 TION M TION M ...
Page 239: ...Materials Dimension RS1 15 Materials 28 M TION TION M ...
Page 240: ...Materials Dimension RS1 30 Materials 29 TION M TION M ...
Page 256: ...Materials Option Metal mounting fittings Materials 45 AL 00582789 01 AL 00582791 01 ...
Page 257: ...Materials Option Metal mounting fittings Materials 46 AL 00582790 01 AL 00582792 01 ...