4. Digital Operator
[
Password setting
]
4−16
■
Description of password function
●
The password function allows selection of a password and protection against unauthorized parameter
changes. Once a password has been set, “status mode” and “monitor mode” can only be used.
Utilize this function to avoid operational mistakes.
■
How to set and release password
Step Input key
Description
Status display
1
MODE
Turn ON the power source or press the
MODE
key to display
the status display mode.
Press the Up key, and the display shown in the right appears.
−PAS−
Display starts blinking
:
password not yet set
→
password
setting
−PAS−
2
Display turns ON
:
Password has been set.
→
Password release
−PAS−
4
WR
Press the
WR
key to display “
0000
”.
0
0000
Pressing the UP key increases the blinking numeric value and the
Down key decreases.
For password setting, use a combination of 4 digit numeric values
and alphabets in hexadecimal.
5
To release the password, input the previously set 4 digit
password.
0
1000
Press the
WR
key, and the display blinks 3 times to write or
release the password.
0
1000
When writing is disabled, “
−Err−
” shows that this is out of
setting range.
“
0000
” and “
FFFF
” are invalid.
6
WR
When release is disabled, “
−Err−
” shows that this is a wrong
password.
−Err−
7
MODE
Press the
MODE
key to return to step 1.
✍
・
For password setting, it is important to make a note of the password and remember it for future reference.
Without the password, it is impossible to release the lock function.
・
The password function is enabled or disabled by turning OFF the control power and then once again
switching it ON. The possible values for a password is a combination of 4 digits from 0 to 9 and A to F.
“
0000
” and “
FFFF
” are invalid. Setting and release of a password cannot be performed by “Setup
software
−
R−Setup
”. Once a password has been set, parameters cannot be changed via
“Setup software
−
R−Setup
”. If parameters are changed via “Setup software
−
R−Setu
p
”, “communication establishment”
will be disconnected.
Statusdispla
monitor
MODE
☜
Summary of Contents for Q1AA04003D
Page 3: ...TYPE S M0006890C Analogue Pulse Input Type Instruction Manual For Rotary Motor E N G L I S H ...
Page 238: ...Materials Dimension RS1 10 Materials 27 TION M TION M ...
Page 239: ...Materials Dimension RS1 15 Materials 28 M TION TION M ...
Page 240: ...Materials Dimension RS1 30 Materials 29 TION M TION M ...
Page 256: ...Materials Option Metal mounting fittings Materials 45 AL 00582789 01 AL 00582791 01 ...
Page 257: ...Materials Option Metal mounting fittings Materials 46 AL 00582790 01 AL 00582792 01 ...