SUNWAY M XS 7500TL
INSTALLATION AND
PROGRAMMING INSTRUCTIONS
20/
148
3.4.
Installation
NOTE
Do not remove the inverter lid during installation
. Removing the lid may
affect the IP rating of the inverter and may damage the internal parts.
Removing the lid voids the inverter warranty.
3.4.1. Environmental Requirements for the Equipment Storage, Installation
and Operation
Model
4600TL
5000TL
6000TL
7500TL
IP Rating
(1)
IP65
IP65
IP65
IP65
Mechanical dimensions w x h x d (mm)
414 x 703 x 260
Weight (kg)
31
31
35
35
Operating ambient temperature (°C)
-25 ÷ +60
Rated operating temperature (°C)
(2)
-25 ÷ +45
Ambient temperature for storage and
transport (°C)
-25 ÷ +70
Maximum number of packed SUNWAY
M XS that can be stacked up
3
Installation site
Outdoor installation, degree of pollution 3 or better.
Do not install the equipment where it is exposed to direct
sunlight or where it is exposed to conductive dust, corrosive
gases, vibrations. Do not install in salty environments.
Altitude
Up to 2000m a.s.l. For altitudes ranging from 2000m to 3000m
a.s.l. derate the output current by 1% every 100m. For higher
altitudes, please contact Elettronica Santerno.
Operating ambient humidity
0 % to 100 %, 1 g/m
3
to 25 g/m
3
, non-condensing and non-
freezing (class 3k3 according to EN 50178).
Storage ambient humidity
0 % to 100 %, 1 g/m
3
to 25 g/m
3
, non-condensing and non-
freezing (class 1k3 according to EN 50178).
Ambient humidity during transport
Max. 100%. Up to 60g/m
3
, condensation may appear when the
equipment is not running (class 2k3 according to EN 50178).
Operating and storage atmospheric
pressure
86 kPa to 106 kPa (class 3k3 and 1k4 according to EN 50178).
Atmospheric pressure during
transport
70 kPa to 106 kPa (class 2k3 according to EN 50178).
Table 1: Environmental requirements
(1)
(2)
The external fans are IP54 rated.
Beyond 45 °C, the SUNWAY M XS automatically decreases its output power in order to avoid
overheating.
CAUTION
Environmental conditions significantly affect the life-expectancy of the
product. Consequently, DO NOT install the product in a location which does
not meet the required specifications.