INSTALLATION AND
PROGRAMMING INSTRUCTIONS
SUNWAY M XS 7500TL
145/
148
o
Field voltage
The power limiting associated with the field voltage decreases the output power every 1 Volt over
740 V by
o
1.1% for size 4600TL, 5000TL, up to a minimum of 10%. This equals 10% of the output
power at 820 V;
o
1.2% for size 6000TL, up to a minimum of 10%. This equals 10% of the output power at 815
V;
o
1.5% for size 7500TL, up to a minimum of 10%. This equals 10% of the output power at 800
V.
80
90
100
0
POWER OUT (%)
HEATSINK
TEMPERATURE (°C)
740
845
100
0
POWER OUT (%)
FIELD VOLTAGE (V)
10
4600TL: 820
5000TL: 820
6000TL: 815
7500TL: 800