INSTALLATION AND
PROGRAMMING INSTRUCTIONS
SUNWAY M XS 7500TL
47/
148
−
Set the DNS (only if you chose the “STATIC” method for the IP address assignment). Setting this
parameter requires knowing the network the inverter is to be connected to.
→
→
→
→
→
Select the
Connectivity
icon
Select the Wi-Fi
Status SSID
Select L311 –
DNS (page 2)
Enter the desired
value and press
Save
Confirm with OK
−
Activate the Wi-Fi connection (3.7.1.1). If the Wi-Fi status icon is green and the screen is similar to
the one in Figure 51, this means that the connection is completed successfully.
NOTE
In the event of failures connecting the inverter to an existing network,
contact your local Network Administrator.
3.7.2. Accessing the Inverter Data
The SUNWAY M XS may be monitored in wireless mode directly by the user, who can check status
information, such as operating measures, alarms tripped and events fired, with no need to implement
demanding wiring solutions.
Data exchange with the inverter is made possible via a Wi-Fi connection operating as described above.
NOTE
Data access is protected by a password associated with the serial number
of the product. The password is given in a form contained in the box of the
product.
The consulting modes below are available only when the inverter is powered on. If the PV field voltage is too
weak (higher than the value set in
P020 – FIELD REFERENCE
), the inverter stops after the time set in
P041
– POWER OFF TIMEOUT
. Parameter
P041
may be changed by the user to keep the inverter on for the
desired time even when the PV field reference is too weak, in order to exploit the functionality described
above. Setting parameter
P041
to 0 fully inhibits the inverter shut down.