SUNWAY M XS 7500TL
INSTALLATION AND
PROGRAMMING INSTRUCTIONS
66/
148
NOTE
Set the ADVANCED level to program the inverter parameters.
The information and configuration variables are grouped as follows:
o
Measures. These values may only be displayed and cannot be changed by the user. Each measure
is identified by letter
M
followed by 3 digits (e.g.
M001
). Measures are detailed as follows in the
sections below:
Mxxx
Range
Internal representation
Value displayed on the touchscreen
display (may be a decimal figure) plus
unit of measure
Name of the
measure
Active
If present, this field indicates if and when the measure is valid. When
this field is not present, the measure concerned is considered as
ALWAYS active.
Address
Modbus address from which the measure is read (integer).
Level
Access level (BASIC / ADVANCED).
Function
Description of the measure.
Table 5: Template of the measure descriptive tables
o
Parameters. These values may be changed by the user in order to configure the inverter operation.
Each parameter is identified by one of the following letters:
P
,
I
,
C
or
R
. Each letter is followed by 3
digits (e.g.
P020
). Parameters are detailed as follows in the sections below:
Pxxx
Range
Internal representation of the
device (integer)
Value displayed on the touchscreen
display (may be a decimal figure) plus
unit of measure
Name of the
parameter
Default
Factory setting of the parameter
(as represented internally).
Factory setting of the parameter (as
displayed) plus unit of measure.
Level
Access level (BASIC / ADVANCED).
Active
If present, this field indicates if and when the measure is valid. When
this field is not present, the measure concerned is considered as
ALWAYS active.
Address
Modbus address the parameter is read from or written to (integer).
Function
Description of the parameter.
Table 6: Template of the parameter descriptive tables