![Saluki S3302SB User Manual Download Page 84](http://html1.mh-extra.com/html/saluki/s3302sb/s3302sb_user-manual_3664696084.webp)
Tel: 886.909 602 109 Email: [email protected]
84
8. Peak menu
·[Maximum Peak]:
Press [Peak]→[Peak Search] to set one marker at the
peak of the trace. The marker frequency and amplitude will be displayed in
the right upper corner of the screen.
·[Next Peak]:
Press [Peak]→[Next Peak] to move the active marker to
next peak associated with the current marker location on the trace. The
lower peak can be rapidly found by repeatedly pressing this key.
·[Next Peak Left]:
Press [Peak]→[Next Pk Left] to find next peak on the
left side of the current marker location.
·[Next Peak Right]:
Press [Peak]→[Next Pk Right] to find next peak on
the right side of the current marker location.
·[Max Search]:
Press [Peak]→[Max Search] to set one marker at the
lowest point of the trace. The marker frequency and amplitude will be
displayed in the right upper corner of the screen.
·[Min Search]:
Press [Peak]→[Min Search] to set one marker at the
lowest point of the trace. The marker frequency and amplitude will be
displayed in the right upper corner of the screen.
·[Peak Track Off On]:
Press [Peak]→[Peak Track Off On] to enable the
peak tracking function. The current marker will search the peak once after
each sweeping. Any operation will not be allowed if the peak tracking
function is disabled.
·[Marker→]:
Press [Peak]→ [Marker→] to set the marker frequency as
the center frequency. This function can be applied to rapidly move the
signal to the screen center.