the following steps of measurement of the sidelobe ratio, pulse width and peak pulse power will not apply. The
resolution bandwidth should be more than 1kHz.
Fig. 4-21 Trace Display in Solid Line Form
c) Read the center frequency of the pulse and amplitude of the main lobe.
Press [Peak].
The marker reading is the center frequency of the pulse and amplitude of the main lobe.
d) Set the marker at the center frequency of the main lobe, and measure the side lobe ratio.
Press [Peak], [Maker], [Delta], [Peak] and [Next Peak].
The amplitude difference between the main lobe and side lobe is the side lobe ratio, as shown in Fig. 4-22.