![Saluki S3302SB User Manual Download Page 68](http://html1.mh-extra.com/html/saluki/s3302sb/s3302sb_user-manual_3664696068.webp)
Tel: 886.909 602 109 Email: [email protected]
68
e) Press [Measure]→[Coverage Map]→[Distance Time]→[Repeat Time], set the time which takes to mark data
once on the map.
f) Press [Measure]→[Coverage Map]→[Distance Time]→[Repeat Dist], set the distance which takes to mark data
once on the map.
g) Press [Measure]→[Coverage Map]→[Start Collection], start the RSSI test and mark the results on the map..
The RSSI measurement of the coverage map is shown in Fig. 4-28 as below:
Fig.4-28 Schematic diagram of RSSI measurement
2) Adjacent channel power ratio measurement
Main operation steps of adjacent channel power ratio measurement:
a) Press [Measure]→[Coverage Map]→[Coverage Map Off On], in the default, the measurement mode is RSSI
measurement after the interference map switch is turned on.
b) Press [Freq]→[Center Freq], set the measured signal frequency.
c) Press [Measure]→[Coverage Map]→[Measurement Setup]→[ACPR], set the ACPR measurement.
d) Press [Measure]→[Coverage Map]→[Measurement Setup]→[ACPR]→[Main Ch BW], set the main channel
bandwidth.
e) Press [Measure]→[Coverage Map]→[Measurement Setup]→[ACPR]→[Adj Ch BW], set the adjacent channel
bandwidth.