9
Maintenance
9-54
RUTHMANN-Steiger
®
TB270
BA.GB.12-27409-05-07-FTA-jr
Change of hydraulic oil according to maintenance list. Every time you
change the oil also maintain the return filter
Clean the area around the hydraulic oil tank in order to avoid that
dirt can get into the tank.
Drain the used oil into a suitable receptacle.
Filling of tank with hydraulic oil over a preceded filter aggregate.
Drain the used oil out of the hydraulic system. Check oil level in-
side the tank. Refill hydraulic oil into the tank over a preceded filter
aggregate.
Exchange return filter element of hydraulic oil according to maintenance
list.
Open filter cover (1) and remove
together with flat sealing (2).
Take the filter element (3) up-
wards out of the filter pot (4) by
slightly turning and pulling it.
Take out filter pot (4) with O-ring
(5) and clean by means of diesel
oil or benzine.
Exchange filter element (3).
Replace damaged seals.
The installation of the filter pot
and of the filter element is to be
carried out in reverse sequence.
Open the ventilation filter (6) and
replace the filter element.
Mounting of the ventilation filter
(6) is carried out in reverse se-
quence
Screw-on the filter cover (1) manually
(Tightening moment 15 Nm).
Summary of Contents for 27409
Page 4: ......
Page 12: ......
Page 20: ......
Page 62: ......
Page 104: ......
Page 162: ......
Page 186: ......
Page 211: ...9 Maintenance BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 9 25 ...
Page 246: ......
Page 252: ......
Page 254: ......
Page 255: ...13 Spare Parts BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 13 1 13 Spare Parts ...
Page 256: ......
Page 258: ...14 Appendix 14 2 RUTHMANN Steiger TB270 BA GB 12 27409 05 07 FTA jr ...
Page 260: ......
Page 261: ...BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 14 1 ...