Interval
Remark,
Component
Work to be carried out
d
300
h
600
h
a
other inter-
vals
Check drained hydraulic oil
,
after 3000 h,
every 6 years at
the latest
Electric system
Emergency -
Visual test
Cut-off
Push button
Check electrical connections for
firm hold and damage
Function test
Signal device
Function test
Perception
Limit switch
Visual test
Check fastening for firm hold
Check electrical connections for
firm hold and damage
Clean mechanical actuation
W,
if necessary
Function test
Approach
Visual test
switch
Check fastening for firm hold
Check electrical connections for
firm hold and damage
Cleaning
W,
if necessary
Function test
Swivelling
Visual test
angle
Check fastening for firm hold
sensor
Check electrical connections for
firm hold and damage
Cleaning
W,
if necessary
Function test
Cable length
Visual test
transducer
Check fastening for firm hold
Check fastening of spring hook /
eyelet bolt
Check well-running
Check electrical connections for
firm hold and damage
Clean traction cable
W,
if necessary
Function test
Inclination
Visual test
meter
Check fastening for firm hold
Check electrical connections for
firm hold and damage
Cleaning
W,
if necessary
Function test
Valve plug
Visual test
Check fastening for firm hold
Check electrical connections for
firm hold and damage
Wiring
Visual test
Check fastening for firm hold
Summary of Contents for 27409
Page 4: ......
Page 12: ......
Page 20: ......
Page 62: ......
Page 104: ......
Page 162: ......
Page 186: ......
Page 211: ...9 Maintenance BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 9 25 ...
Page 246: ......
Page 252: ......
Page 254: ......
Page 255: ...13 Spare Parts BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 13 1 13 Spare Parts ...
Page 256: ......
Page 258: ...14 Appendix 14 2 RUTHMANN Steiger TB270 BA GB 12 27409 05 07 FTA jr ...
Page 260: ......
Page 261: ...BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 14 1 ...