Lifting of boom not possible / is interrupted.
Possible cause
Remedy
Jacks of Steiger not properly
extended.
Extend jacks properly.
Lowering of boom not possible / is interrupted.
Possible cause
Remedy
LML-cut-off
Reduce load moment by e. g.
retraction of telescope,
reduction of working cage
load.
Working cage rotated too far to
the left or right.
Rotate working cage back toward the
centre position.
Chain for power track is slack.
The cable /hose drum does not
roll up the chain for power track.
Carry out for a short time a movement
so that the chain for the power track
will be tightened and be rolled off from
the cable / hose drum, e.g.
move boom upwards,
extension of telescope.
Attention
: Carry out the movement
with precaution while observing the
cable / hose drum. If the chain can af-
terwards be rolled up or off resp. with-
out problems, however the cause
must be found out. If necessary, an
existent default must be eliminated.
Delayed cage levelling.
Possible cause
Remedy
Operating temperature of hy-
draulic oil in hydrostate still not
reached (cold hydraulic oil e.g.
in winter time).
Increase oil temperature. Change the
inclination of the unmanned working
cage several times by means of the
movements „Cage up“ and „Cage
down“ using the emergency control
system.
Reduce speed, move joystick not so
far.
Summary of Contents for 27409
Page 4: ......
Page 12: ......
Page 20: ......
Page 62: ......
Page 104: ......
Page 162: ......
Page 186: ......
Page 211: ...9 Maintenance BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 9 25 ...
Page 246: ......
Page 252: ......
Page 254: ......
Page 255: ...13 Spare Parts BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 13 1 13 Spare Parts ...
Page 256: ......
Page 258: ...14 Appendix 14 2 RUTHMANN Steiger TB270 BA GB 12 27409 05 07 FTA jr ...
Page 260: ......
Page 261: ...BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 14 1 ...