9
Maintenance
BA.GB.12-27409-05-07-FTA-jr
RUTHMANN-Steiger
®
TB270
9-37
9.4.5.3
Bearing points / Bolt locking
Bearing points and bolt locking must be checked for:
good condition and cleanness,
wear, fissures and damage,
well-running of bearing,
firm hold of screw fittings of bolt locking
If bolt locks get loose the reason must be ascertained and the fault must
be rectified. We recommend having the repair of defective bearings and
bolt locks carried out by the Ruthmann-after-sales-service or by person-
nel authorized by us accordingly.
Clean bearing points from outside. Do not use high-pressure cleaner
and / or chemical detergents.
Grease DU-bush-bearing points with provided lubrication point (grease
nipple) according to maintenance list.
Cover the DU-bush-bearing points without any grease nipple with oil at
the separation points / contact points.
9.4.5.4
Bearing points with plastic bushes
Visual test concerning condition and cleanness, firm hold, fissures and
damage.
Plastic bushes must be free of grease and oil -
do not
grease or oil.
Plastic bushes must be free of paint -
do not
cover with paint.
Clean regularly bearing points from outside (e.g. by means of a cloth).
Do not use high-pressure cleaner and chemical detergents!
Summary of Contents for 27409
Page 4: ......
Page 12: ......
Page 20: ......
Page 62: ......
Page 104: ......
Page 162: ......
Page 186: ......
Page 211: ...9 Maintenance BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 9 25 ...
Page 246: ......
Page 252: ......
Page 254: ......
Page 255: ...13 Spare Parts BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 13 1 13 Spare Parts ...
Page 256: ......
Page 258: ...14 Appendix 14 2 RUTHMANN Steiger TB270 BA GB 12 27409 05 07 FTA jr ...
Page 260: ......
Page 261: ...BA GB 12 27409 05 07 FTA jr RUTHMANN Steiger TB270 14 1 ...