72 Firmware Download
KP-3016/KP-3016A Series
Bosch Security Systems, Inc.
Technical Manual
F.01U.315.927
Rev. 02
Download Firmware Using the Bootloader
The
Bootloader
is used to upload a new bootloader image or to upgrade the keypanel firmware if it is corrupt or fails in such
a way that makes normal downloading of new firmware impossible.
IMPORTANT:
If the keypanel firmware is corrupt, the panel may boot automatically into the bootloader. However, if
the keypanel firmware appears valid, but fails to run properly, you may need to force the keypanel into
the bootloader to load new keypanel firmware. You can also force the keypanel into the bootloader in
order to download a new bootloader image (though this can also be done through the keypanel
firmware, see “Enable Downloading New Bootloader from the Keypanel” on page 74.
Run the Bootloader
To
run the bootloader
, do the following:
1.
Power
off
the keypanel.
2.
Verify the
KP-3016/3016A is powered off
, but still connected to the FRAME.
3.
At the same time, press and hold
keypanel key 15 in the listen position (up) and keypanel key 16 in the talk
position
(down)
, while you connect the
power cord
to the keypanel.
KP-3016/3016A - Boot Loader Waiting for download... appears in the panel display
.
4.
In AZedit, from the Status menu, select
Software Versions
.
The Software Versions popup menu appears
.
5.
From the Software Versions popup menu, select
Keypanels
.
The Keypanel Version Information window appears.