KP-3016/KP-3016A Series
KP-3016/3016A Menu System 123
Bosch Security Systems, Inc.
Technical Manual
F.01U.315.927
Rev. 02
Service Menu, Display
The
Display
menu is used to enable the menu context, display speaker volume and to switch the display to emulate a KP-32
keypanel.
Display Volume
The
Display Volume
feature is used to enable always-on display of the volume bar for Headset, Matrix, or Speaker, depending
on what is selected from the encoder knobs.
KP32 Emulation
The
KP32 Emulation
is used to switch the display alphas and background to emulate the KP32 with the black background and
green lettering.
IMPORTANT:
Only the display of key and key assignment changes, the menu structure and other display elements do
not revert to the KP32 display.
To
activate KP32 Emulation
, do the following:
1.
Starting at the Service|Display menu, select
KP32 Emulation
.
2.
Press the
SEL button
.
Disabled and Enabled appear in the panel display
.
3.
Using the AUX/MENU shaft encoder, select
Enabled
.
4.
Press the
SEL button
.
The display panel changes to the KP32 Emulation mode
.
Service Menu, Intercom Mode
The
Intercom Mode
menu is used to select the type of firmware you have in your intercom so the keypanel can display alphas
in the correct font/language and modify the behavior of some functions to match the intercom behavior.
Available options are
Alternate
and
Standard
.
NOTE:
Standard mode is the default and should be used in most cases. Alternate mode is primarily used for intercoms
running Japanese firmware.
To
select the intercom mode
, do the following:
1.
Starting at the Service|Intercom Mode menu, select
Alternate
or
Standard
.
An arrow appears next to selected option
.
2.
Press the
SEL button
.
The selections Cancel and Save and Restart appear.
3.
Using the AUX/MENU shaft encoder, select
Cancel
to cancel out of the action.
OR
Using the AUX/MENU shaft encoder, select
Save and Restart
to save the changes.
4.
Press the
SEL button
.