BW/H Komfort
48000120_r
oth_bwh_k
omf
or
t.mon06304.ind
d
|
66
Pump starts for a short moment, switches-off, switches-on
again, etc. („controller jitting“)
Too little temperature
difference at the cont-
roller?
no
yes
Wrong mounting of
collector sensors?
yes
Change
∆
Ton and
∆
Toff
accordingly.
Mount the collector sen-
sor at solar feed flow
(warmest collector out-
put); use immersion sleeve
of the respective collec-
tor.
Pump starts up very late and stops working soon.
The temperature diffrence between store and collector
increases enormously during operation; the collector
circuit cannot dissipate the heat.
Collector circuit pump
defect ?
no
yes
Heat exchanger calcified?
yes
Control / replacement
Decalification
no
Heat exchanger plugged?
yes
no
Cleaning
Heat exchanger too
small?
yes
New calculation of the
dimension.
no
Plausibility control of
the option tube collec-
tor special function
Change
∆
Ton and
∆
Toff
accordingly.
o.k.
Too little temperature
difference at the cont-
roller?
no
yes
Plausibility control of ma-
ximum store temperature
Tstmax and security switch-
off of the store.
o.k.
no
no
Pump is overheated, but no heat transfer from collector
to the store, feed flow and return flow are the same warm;
perhaps also bubble in the lines.
Exhaust the system; incre-
ase the system pressure
to at least static primary
pressure plus 0,5 bar; if
necessary continue to
increase pressure; switch
the pump for a short time
off and on.
Air in the system?
no
yes
Is the collector circuit
plugged at the dirt trap?
yes
Clean the dirt trap.
4. Various:
B
Summary of Contents for BW/H Komfort
Page 34: ......
Page 68: ......
Page 102: ......
Page 136: ......
Page 137: ...Roth BW H Komfort Manual Roth BW H Komfort Montaje Conexiones Funcionamiento Errores Ejemplos...
Page 170: ...BW H Komfort 48000120_roth_bwh_komfort mon06304 indd 170...
Page 171: ...BW H Komfort 48000120_roth_bwh_komfort mon06304 indd 171...
Page 172: ......