Controller Functionality
AYC-W6500 Installation Manual
Page 49
I
Auxiliary Mode 6
Auxiliary Input behavior
f the auxiliary input is opened and no
valid door entry code was entered, the
auxiliary output opens after a set duration.
Auxiliary Output behavior
Wh
ns
en triggered, the auxiliary output ope
after a set duration.
(Auxiliary output is normally closed)
Auxiliary Output trigger
The auxiliary output is triggered if no v
door entry code was entered and the
auxiliary input is opened.
alid
Settings
conds before the auxiliary output
Time in se
opens (01-99).
Example Use:
Using the auxiliary input and outp
ct if the door has been forced
open.
If the door remains open after a s
but no valid door entry code
was entered, then the auxiliary o
ds a
cted t
The auxiliary output is connected
ut, dete
et duration
utput informs an alarm system or soun
siren.
The auxiliary input is conne
o the door sensor output.
to the alarm system.