Reader Functionality
Note:
By default, the backlight is set to Always Off (code 5000)
Setting Lockout
Lockout is intended to stop users from guessing the unit's programming
code.
When the programming code is entered incorrectly too many times, the
keypad locks and cannot be used for a set period of time. The number of
tries and the lockout duration are set in the lockout menu.
To Set the Keypad Lockout Preferences:
1. Enter
Programming
Mode
(see
Entering Programming Mode, page
17).
2. Press
“6” to enter Menu 6.
6
3. Enter code according to the following:
AYC-W6500 Installation Manual
Page 24
Digit 1
Digit 2
Digit 3
Digit 4
4 1-9 sets the number of
consecutive wrong code
attempts before a lockout
occurs.
0 deactivates the Lockout
function.
0-99 sets the lockout
duration in seconds,
divided by a factor of ten.
Example: a value of "20"
sets the lockout duration
at 200secs.
When a lockout is
triggered, the unit will not
function for this period of
time.
4. System returns to Normal Access Mode.
•
The unit sounds three beeps.
Controlling Operation by Auxiliary Input (LED_CTL)
When set, the unit can be toggled between Normal Mode and
Secure Mode using the Auxiliary input, "LED_CTL".
Alternatively, it is possible to control the unit's Reader status LED or
the buzzer from the LED_CTL input. When the LED_CTL input is set,
the LED will turns green or the buzzer will sound.
To Control the Unit via the LED_CTL Auxiliary Input:
1. Enter
Programming
Mode
(see
Entering Programming Mode,
page 36).
6
2. Press
“6” to enter Menu 6.