Reference Manual
00809-0100-4663, Rev BA
January 2010
Rosemount 8732
6-10
Figure 6-2. 45° Electrode Plane
To insure accuracy of resistance readings, zero out multimeter by shorting
and touching the leads together.
Table 6-6. Uninstalled Rosemount 8705 / 8707
Flanged Sensor Tests
Measuring at Connections
Hazardous Location Certifications
N0
N5, KD
18 and Electrode
(1)
(1) It is difficult to tell from visual inspection alone which electrode is wired to which number terminal in
the terminal block. Measure both electrodes. One electrode should result in an open reading, while
the other electrode should be less than 275
.
19 and Electrode
17 and Grounding Electrode
17 and Ground Symbol
17 and 18
Open
Open
17 and 19
Open
Open
17 and 1
Open
Open
Table 6-7. Uninstalled Rosemount 8711 Wafer Sensor Tests
Measuring at Connections
Hazardous Location Certification
N0
N5, E5, CD
18 and Electrode
(1)
(1) Measure the electrode closest to the junction box
19 and Electrode
(2)
(2) Measure the electrode farthest away from the junction box.
17 and Grounding Electrode
17 and Grounding Symbol
17 and 18
Open
Open
17 and 19
Open
Open
17 and 1
Open
Open
275
61k
R
75k
275
61k
R
75k
0.3
0.3
0.3
0.3
0.3
61k
R
75k
275
61k
R
75k
0.3
0.3
0.3
0.3
Summary of Contents for 8732 Series
Page 2: ......
Page 4: ......
Page 10: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 TOC 6 ...
Page 26: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 2 14 ...
Page 38: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 3 12 ...
Page 92: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 A 8 ...
Page 186: ...Reference Manual 00809 0100 4663 Rev BA January 2010 Rosemount 8732 H 8 ...
Page 189: ......