Connect coil drive and electrode cables as shown in Figure E-22.
Yokogawa Sensor to
Rosemount 8732
Transmitter
Figure E-22. Generic Wiring
Diagram for Yokogawa Sensors
and Rosemount 8732
Table E-23. Yokogawa Sensor
Wiring Connections
Electrodes
Coils
Chassis Ground
ROSEMOUNT 8732
TRANSMITTER
YOKOGAWA
SENSORS
Ex 2
Ex 1
A
B
C
Fuse
Rosemount 8732
Yokogawa Sensors
1
EX1
2
EX2
Chassis Ground
17
C
18
B
19
A
This is a pulsed DC magnetic flowmeter.
Do not connect AC power
to the sensor
or to terminals 1 and 2 of the
transmitter
, or replacement of the
electronics board will be necessary.