Series 1800 (Version 2)
Sensor to
Rosemount 8732
Transmitter
Connect coil drive and electrode cables as shown in Figure E-13.
Figure E-13. Wiring Diagram for
Foxboro Series 1800 (Version 2)
and Rosemount 8732
Table E-14. Foxboro Generic
Sensor Wiring Connections
FOXBORO SERIES
1800 SENSOR
(VERSION 2)
ROSEMOUNT
8732
TRANSMITTER
Coil Connections
Electrode
Connections
GND
L2
L1
White
Black
Shield
Rosemount 8732
Foxboro Series 1800 Sensors
1
L1
2
L2
Chassis Ground
17
Any Shield
18
Black
19
White
This is a pulsed DC magnetic flowmeter.
Do not connect AC power
to the sensor
or to terminals 1 and 2 of the
transmitter
, or replacement of the
electronics board will be necessary.