Connect coil drive and electrode cables as shown in Figure E-21.
Yamatake Honeywell
Sensor to
Rosemount 8732
Transmitter
Figure E-21. Generic Wiring
Diagram for Yamatake
Honeywell Sensors and
Rosemount 8732
Table E-22. Yamatake
Honeywell Sensor Wiring
Connections
Electrodes
Coils
Chassis Ground
ROSEMOUNT 8732
TRANSMITTER
YAMATAKE
HONEYWELL
SENSORS
Y
X
A
B
C
Fuse
Rosemount 8732
Yamatake Honeywell Sensors
1
X
2
Y
Chassis Ground
17
C
18
B
19
A
This is a pulsed DC magnetic flowmeter.
Do not connect AC power
to the sensor
or to terminals 1 and 2 of the
transmitter
, or replacement of the
electronics board will be necessary.