Chapter 5: Subsystem Maintenance and Upgrading
Replacing
a MUX Kit
5-21
Step 4.
Remove the drive tray
by pulling it one inch away from the
drive bay. Wait for at least 30 seconds for the disk drive to
spin down (if the disk drive is removed for a different purpose,
e.g., cloning the members of a logical drive or Copy &
Replace), and then gently and carefully withdraw the drive
tray from the chassis.
Figure 5-20: Removing a Drive Tray
Step 5.
Remove the four (4) retention screws
that secure the hard
drive from the sides of the drive tray (two on each side). (See
Figure 5-21
)
Figure 5-21: Removing the Hard Drive
Step 6.
Install the replacement drive. Please refer to the complete hard
drive installation procedures in
Section 2.6.
Step 7.
Re-install the drive tray back to the subsystem.
Refer to
Section 2.7
.
5.8 Replacing a MUX Kit
If a MUX kit is damaged or fails, often identified as drive-side signal
glitches, follow these instructions to replace it: