Galaxy A16F-R2431 Installation and Hardware Reference Manual
3-8
Sample Topologies
DIP Switch Mode Setting
Switches #1
to #3
Enclosure ID: defaulted to represent number “0”. No need
to change.
Switch# 4
0: Hub Enabled; 1: Hub Disabled
Table 3- 1 DIP Switch Mode Settings
3.4 Sample Topologies
Use the Fibre ports, marked as “
CH0
” and “
CH1
”, on the controller
modules to connect to host computer(s) or to the switched fabric.
3.4.1 Multiple RAID, Fault-tolerant Connection
The A16F-R2431 readily fits into a Fibre Channel storage environment.
Shown below is a DAS configuration using cross-links among parallel
subsystems.
One major concern for this topology is to avoid ID conflicts on the host
channels. When cascaded, logical drives from different RAID subsystems
should be associated with different host channel IDs.