Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
B0046191 / Rev. 1.12
Communication with the PLC
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
79
Bytes 18 - 20:
Byte.Bit
PLC -> R1000 (BIN)
R1000 -> PLC (BOUT)
18.0
---
Type of material at sensor 3 (here always 1)
18.1
---
Current measuring program S3: Teach-In performed
18.2
Zero adjust (sensor 3)
---
18.3
Teach-In 1-sheet (sensor 3)
---
18.4
---
Warning
2)
18.5
---
0-sheet
2)
sensor 3
18.6
---
1-sheet
2)
sensor 3
18.7
---
2-sheet
2)
sensor 3
19.0
---
High byte thickness value
4)
(sensor 3)
19.1
---
19.2
---
19.3
---
19.4
---
19.5
---
19.6
---
---
19.7
---
---
20.0
---
Low byte thickness value
4)
(sensor 3)
20.1
---
20.2
---
20.3
---
20.4
---
20.5
---
20.6
---
20.7
---
2), 4)
Footnotes see Table “Bytes 21 to 23”