Double Sheet Detector R1000 series E20
with integrated fieldbus interface
B0046191 / Rev. 1.12
Operation
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
127
8.4 Teach-In
1
Push the
MENU
key, switch to "change" with the
key and confirm with the
ENTER
key
2
Enter the password
3
Switch to "program parameter" and confirm with
ENTER
key
4
Select the desired program number at the control unit
5
Switch to Teach-In (parameter 7)
6
Select "teach-in" and confirm with
ENTER
key
7
The message "attach sheet" appears, then confirm with
ENTER
key
8
After "teach-in active" the message "Teach-In value: x.xx" is shown – the value can be
corrected with the
keys (the adjustment is not possible if "%mm" or "%inch" were selected
in the configuration menu option 2)
9
Return to the measurement mode with the
MENU
key
Attention
The actual measured value cannot deviate too far from the nominal
dimension, otherwise the fault message "teach-in fault" appears.
(this restriction is not valid if in the configuration option 2 "%mm" or
"%inch" were selected).
The exact teach-in procedure is described in the chapter “7.6 Program parameter 7: teach-in".
Note
High-alloy steels (e.g. TRIP steel) generate a significantly lower
measurement signal than normal steel. Deviations of up to 30% are
possible. To prevent this, the nominal thickness should be set to a
smaller value if necessary. This can be necessary for thin sheets less
than 0.5 mm thickness.
Example: Nominal thickness 2.00 mm – manual Teach-In
•
The micrometer measures actual value to be: 1.92 mm.
•
The teaching shows a value of: 1.89 mm.
•
The display value is now corrected to 1.92 mm.