Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Technical data
B0046191 / Rev. 1.12
24
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
2.6.2
Sensor cable SM12CPS for sensors P36GS, P42GS, P75GS and P75VGS
Fig. 11: Sensor cable SM12CPS
Cable types for the P36GS, P42GS, P75GS and P75VGS sensor (order data):
•
SM12CPS-GG (straight receptacle at the sensor)
•
SM12CPS-GW (right angle receptacle at the sensor)
The standard length is 5 meter. Cable length up to 50 meter made to order, longer cables please
enquire.
Note
In particular with larger lengths the sensor cable should not be placed
directly adjacent to cables with large noise potential.
The cable is drag cable suitable and oil resistant.
Cable type:
•
Oilflex FD810CY 2 x 1mm
2
•
Unitronic FDCP (TP) plus 1 x 2 x 1mm
2
(UL / CSA)
78
5
1
2
3
6
4
Cable plug
Plug contacts
1)
1)
View plug side
1
black (1) [white]
2
black (2) [brown]
5
blank (Shield)
Cable socket
to sensor
Right angle cable socket (optional)
black (1) [white]
black (2) [brown]
blank (shield)
5
6
1)
View contact side
Receptacle contact
1)
N.C.
1 - 4
3 - 4 N.C.
OILFLEX FD810CY 2 x 1 mm²
[
Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
Ø 30
75
53
OILFLEX FD810CY 2 x 1 mm²
[
Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
*
The maximum allowed fastening torque is 0.6 NM
- It is not allowed to fasten the locking screw with pliers, pipe wrenches or similar!
- We request to tighten the locking screw by hand or to use a fastening tool with torque control
e.g. Binder Tool 713-825, Binder Order no. 07 0079 000
http://www.binder-connector.de/de/zubehoer/82149
Ø 20
62
*
t
o control unit / to cable extension
Cable socket at sensor side
Cable plug at unit side
Sensor Control
unit
A
B
C
black (1) [white]
black (2) [brown]
blank (Shield)
2
3
4
5
P36GS
P42GS
6
P75GS
P75VGS
1
2
3
4
5
6
1
2
3
4
5
1
2
3
4
5
C