Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
B0046191 / Rev. 1.12
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
119
System parameter 11:
Specifying the number of connected sensors (only for 4P unit).
Fig. 87: Specifying the number of sensors
Possible choices:
• 1
sensor
• 2
sensors
• 3
sensors
• 4
sensors
Attention
Changing the current configuration will delete all stored program
parameters. Then for all sheet types the nominal thickness values
must be re-entered and the Teach-In must be performed again.
System parameter 12:
Specifying the type of actuating the sensors (only for 4P control unit).
Fig. 88: Sensor selection
Possible choices:
•
External:
Switching of sensor is accomplished via the external PLC lines
„Sensor selection“ A and B.
Advantage: faster sensor switching procedure.
•
Program:
Switching of sensor is accomplished via program selection.
A sensor (sensor sequence) is assigned to each program.
Advantage: less programming effort.
System parameter 13:
not available (reserve).
Fig. 89: Reserved system parameter
system parameter 11
number of sensors: 1
system parameter 12
sel. sensor: ext.
system parameter 13
not available