4.3.7
Clamping bracket SHK
The clamping bracket SHK can be used for the mounting of the spring loaded sensor brackets
SHS...GS or SH...GS.
All Dimensions are in mm. Tolerance:
± 0.2 mm.
Fig. 33: Clamping bracket SHK
4.3.8 Electromagnetic
interference
Electromagnetic interference can affect the measuring accuracy of the sensor. Therefore the
sensors should not be installed close to devices which cause electromagnetic interference. Such
devices are e.g. frequency converters, servo motors or proximity switches on inductive basis. In
case of switching magnets a minimum distance of 20 mm should be observed in order to avoid
feedback.
The sensor cables should not be placed directly adjacent to cables with large interference potential,
e.g. power supply cable. This applies especially to longer cable lengths.