Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Mounting
B0046191 / Rev. 1.12
54
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Replacing the gasket
Pull the rubber disc over the lower edge. Pay attention for undamaged sealing lips at the inner and
outer edge as well as for uniform projection of the sealing edge. The gasket can be bilaterally used.
Pos: 35 /Doppelblech/Sensoren/Sensorhalterungen/Gefederte Sensorhalterung SHX42-DL @ 3\mod_1449659030495_501.docx @ 23798 @ 34 @ 1
4.3.5
Spring mounted sensor bracket SHX42-DL
Features:
•
Very stiff in extended condition, for lateral acceleration up to 2g. Thus precise putting on the
sheet without canting, also on splayed sheets or bevelled TWB stacks.
•
Very elastic in pressed condition and movable into all directions. Lateral motions of the sheet
being transported can thereby also be compensated up to approx. ±1 centimetre.
•
No appearance of lateral forces, thus only minimal wear.
•
Fast suction and releasing of the sheets due to small air volume under the suction hood,
compared to bellows suction cups.
•
Bellows suction cup with a shore grade of 55
•
Good access to the sensor from above, no counter-nut required.
•
Fixing of sensor by lateral headless screw with plastic pressure pad.
Fig. 29: Sensor bracket SHX42-DL
Fig. 30: Base plate for sensor bracket SHX42-DL
Pos: 36 /Doppelblech/Sensoren/Sensorhalterungen/Gefederte Sensorhalterung SHS42G-FB mit Faltenbalgsauger @ 1\mod_1215005514906_501.docx @ 6410 @ 3 @ 1
150
110 Ø
ma
x
. 12
0