Electrical installation
B0046191 / Rev. 1.12
68
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
5.2.5.10 EtherCAT
Round-shape connector, M12, 4-pin., D-coded,
socket contact at control unit
IN (Pos. C2)
OUT (Pos. C1)
View: Plug side
Pin 1
TD +
Pin 2
RD +
Pin 3
TD –
Pin 4
RD –
Plug enclosure
Shield
The corresponding cable plugs are part of the standard scope of supply.
5.2.6 Sensor
connection (pos. D)
The sensor connection at the control unit is a quick disconnect type.
The following cables are to be used:
• SM12CPS-GG and SM12CPS-GW for P36GS, P42GS, P75GS and P75VGS
• SM12CPM12S-GG and SM12CPM12S-GW for P30GS and P42AGS
• SM12CPPPS-GG and SM12CPPPS-GW for P128GPPS
Connector at control unit
(pos. D)
Manufacturer / types / notes
P30GS
P42AGS
P75VGS
P128GPPS
M12,
5-pin
Female connector at control unit
Binder, series 713
View: Plug side
pin 1
Sensor signal 1
pin 2
Sensor signal 2
pin 3
-
pin 4
-
pin 5
Shield
5.2.7
Connection of earth ground (pos. E)
The enclosure of the R1000 has an M6 threaded screw for earth ground connection. This screw
must be connected to the earth ground of the equipment with a copper wire gauge of 1.5 mm²
cross section.
Attention
The earth ground/central machine ground must not be
connected to + 24 VDC.