Electrical installation
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
63
5.2.4
Connection of Optocoupler outputs and RSI interface (pos. B1 and B2)
Note
The Optocoupler inputs are placed at the supply voltage connection
(pos. G)
The RSI enables the operation of future ROLAND sensors which have not only the signal output
but also the RSI interface.
On the following pages the pin configuration of the optocoupler outputs and the RSI (ROLAND
serial interface) are described.
Connector at control unit
Manufacturer / types / notes
Optocoupler output
M8, 8-pin, A-coded, female
connector at control unit
Binder type 713 and others
View: plug side
pin 1
+24VDC
External supply 24V DC
pin 2
OUT0
1st optocoupler output
pin 3
OUT1
2nd optocoupler output
pin 4
OUT2
3rd optocoupler output
pin 5
OUT3
4th optocoupler output
pin 6
OUT4
5th optocoupler output
pin 7
-
pin 8
Shield / ground
Internal at enclosure (common)
RSI
M12, 5-pin, A-coded, female
connector at control unit
Binder type 713 and others
View: plug side
pin 1
Shield / ground
Internal at enclosure (common)
pin 2
-
pin 3
GND
pin 4
RSI- High
pin 5
RSI- High
Table: Pin configuration of optocoupler output and RSI interface
Optocoupler outputs for fast switching operation
For reasons of velocity and for diagnostic purposes it could be useful to issue the relevant
switching signal 0-sheet, 1-sheet, 2-sheet via a real-time interface. Latency periods and cycle times
of fieldbus communications are eliminated.
Signal Meaning
Notes
OUT0
0-sheet
1st optocoupler output
OUT1 1-sheet
2nd
optocoupler
output
OUT2 2-sheet
3rd
optocoupler
output
OUT3 Enable
4th
optocoupler
output
OUT4 Warning
5th
optocoupler
output
2
1
6
5
4
3
7
8
1
2
5
4
3