TRIGger[:SEQuence]:LEVel:VIDeo
<VideoTrigLevel>
This command defines the level of the video trigger.
Video trigger is available for time domain measurements (span
=
0).
Parameters:
<VideoTrigLevel>
Range:
0 PCT to 100 PCT
*RST:
50 PCT
Example:
TRIG:LEV:VID 50PCT
Sets the trigger level to 50%.
TRIGger[:SEQuence]:SLOPe
<TriggerSlope>
This command selects the slope of the trigger signal.
The trigger slope applies to all trigger sources.
Parameters:
<TriggerSlope>
POSitive | NEGative
*RST:
POSitive
Example:
TRIG:SLOP NEG
TRIGger[:SEQuence]:SOURce
<TriggerSource>
This command selects the trigger source.
Parameters:
<TriggerSource>
IMMediate | EXTernal | VIDeo | GATed
IMMediate
Selects Free Run measurements.
EXTernal
Selects an external trigger.
VIDeo
Selects the video trigger.
*RST:
IMMediate
For more information, see chapter "Setting the Sweep".
Example:
TRIG:SOUR EXT
Selects the external trigger input as source of the trigger signal.