User Manual 1173.9286.02 ─ 15
CALCulate<n>:LIMit<k>:UPPer[:DATA]
<LimitLinePoints>
This command defines the vertical definition points of an upper limit line.
Suffix:
<n>
.
irrelevant
<k>
Parameters:
<LimitLinePoints>
Variable number of level values.
Note that the number of vertical values has to be the same as
the number of horizontal values set with
FSW either adds
missing values or ignores surplus values.
*RST:
Limit line state is OFF
Manual operation:
See
CALCulate<n>:LIMit<k>:UPPer:SHIFt
<Distance>
This command moves a complete upper limit line vertically.
Compared to defining an offset, this command actually changes the limit line definition
points by the value you define.
Suffix:
<n>
.
irrelevant
<k>
Parameters:
<Distance>
Defines the distance that the limit line moves.
Usage:
Event
Manual operation:
See
8.10 Graphical Display of Phase Noise Results
The following commands are necessary to set up and configure the graphical phase
noise result displays.
CALCulate<n>:MATH[:EXPression][:DEFine]
....................................................................117
..........................................................................................117
DISPlay[:WINDow]:TRACe<t>:MODE
.............................................................................. 118
DISPlay[:WINDow]:TRACe<t>:SMOothing:APERture
........................................................ 118
DISPlay[:WINDow]:TRACe<t>:SMOothing[:STATe]
........................................................... 118
DISPlay[:WINDow]:TRACe<t>:SMOothing:TYPE
.............................................................. 119
DISPlay[:WINDow]:TRACe<t>:SPURs:SUPPress
..............................................................119
DISPlay[:WINDow]:TRACe:X[:SCALe]:HDECade
.............................................................. 119
DISPlay[:WINDow]:TRACe:X[:SCALe]:SCOPe
..................................................................120
DISPlay[:WINDow]:TRACe:X[:SCALe]:STARt
................................................................... 120
Graphical Display of Phase Noise Results