Numeric Measurement Modes
R&S
®
EVSG1000
113
User Manual 1178.6227.02 ─ 06
Status flags
The "STIOCPMV" value contains status flags, if applicable:
●
S
: Start (started manually)
●
T
: Triggered (externally)
●
I
: Invalid
●
O
: Overload (RF input signal too high)
●
C
: Corrected (includes RF input correction factor)
●
P
: PPS-synced
●
M
: Morse ID available
●
V
: Valid signal (ILS LOC/GP and VOR only)
Remote commands for retrieving results:
4.3.3
Configuring VOR Measurements
The following settings are available for VOR measurements.
Settings for recording, including trigger settings, are described in
VOR measurements on LF input
Using the option R&S
EVSG1-K7, you can also analyze the AF components of the
VOR signal to determine AF parameters of the carrier.
Furthermore, you can use the LF input to measure signals with a very low intermediate
frequency (<25
kHz). Such signals are provided as output at test points of a transmit-
ter, for example, for tuning purposes.
For details on configuring a VOR measurement on LF input, see
General Measurement Configuration
.................................................................... 113
Channel Frequency Configuration (CH FREQ)
..................................................... 115
Setting the Measurement Time (MTime)
............................................................... 117
4.3.3.1
General Measurement Configuration
Access
: [Config]
VOR Mode (Option R&S
EVSG-K2)