Remote Commands
R&S
®
EVSG1000
321
User Manual 1178.6227.02 ─ 06
SUBCARR_K5
Queries K5 subcarrier harmonic of VOR signal in "VOR" mode.
Return values:
<Distortion>
Distortion 5
th
order
Default unit: dB
Manual operation:
See
10.4.3
Deprecated Commands
The following commands are maintained for compatibility with former
Rohde
&
Schwarz analyzers only. For new remote control programs, use the com-
Chapter 10.4.1, "Configuring VOR Measurements"
Chapter 10.12, "Data Management"
FA2
This command activates the continuous repetition of a set of values. The output rate is
defined by the current measurement time.
All values are transmitted as integer values, multiplied with a constant factor.
The following multipliers are applied:
●
10 for RF level [dBm]
●
100 for Bearing [DEG]
●
100 for AM-Mod30 [%]
●
100 for AM-Mod9960 [%]
●
10 for FM-Deviation [Hz]
●
10 for FM-Index [1]
The command FA0 stops the output.
Return values:
<State>
READY.
The command was executed successfully.
FA0
This command stops the continuous output that was started with FA2.
Return values:
<State>
READY.
The command was executed successfully.