![Rohde & Schwarz EVSG-B1 User Manual Download Page 266](http://html.mh-extra.com/html/rohde-and-schwarz/evsg-b1/evsg-b1_user-manual_1477820266.webp)
Remote Commands
R&S
®
EVSG1000
266
User Manual 1178.6227.02 ─ 06
SETUP:TIMESYNC?
SETUP:TIMESYNC
<Source>
Defines or queries the time source with which the R&S
EVSG1000 clock is synchron-
ized. If the R&S
EVSG1000 clock differs from the selected synchronization source time
by more than 1000
ms, the R&S
EVSG1000 clock is adjusted accordingly.
Parameters:
<Source>
OFF
No synchronization is performed for the internal R&S
EVSG1000
clock.
GPS
Synchronization with a connected GPS (see the main
R&S
EVSG1000 User Manual).
Example:
SETUP:TIMESYNC OFF
10.1.9
System Settings
The following commands are required to configure basic system settings.
................................................................................266
....................................................................................266
................................................................................................ 267
..........................................................................................267
DISPLAY_BRIGHTNESS_BATTERY
<Percentage>
This command sets the display brightness in battery mode.
Parameters:
<Percentage>
numeric value
Setting of display brightness.
Range:
0 to 100
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
DISPLAY_BRIGHTNESS_MAINS
<Percentage>
This command sets the display brightness in mains mode.
Common Instrument and Measurement Setup