![Rohde & Schwarz EVSG-B1 User Manual Download Page 254](http://html.mh-extra.com/html/rohde-and-schwarz/evsg-b1/evsg-b1_user-manual_1477820254.webp)
Remote Commands
R&S
®
EVSG1000
254
User Manual 1178.6227.02 ─ 06
SETUP:AF_SOURCE_OUT
<Source>
Selects the source for "AF Out" for active RX-Board.
Parameters:
<Source>
AM_DEMOD_CC_BB
AM Demodulation at the center carrier
AM_DEMOD_UC
AM Demodulation at the upper carrier of a 2F ILS signal
AM_DEMOD_LC
AM Demodulation at the lower carrier of a 2F ILS signal
FM_DEMOD_CC
FM Demodulation at the center carrier
FM_DEMOD_UC
FM Demodulation at the upper carrier of a 2F ILS signal
FM_DEMOD_LC
FM Demodulation at the lower carrier of a 2F ILS signal
Return values:
<State>
READY.
The command was executed successfully.
SETUP:ANALOG_OUT1
<Source>
Selects the source for Analog Out 1.
Parameters:
<Source>
CH1_DDM | CH2_DDM | CH1_BB_FULL | CH2_BB_FULL |
CH1_BB_AUDIO | CH2_BB_AUDIO
Return values:
<State>
READY.
The command was executed successfully.
SETUP:ANALOG_OUT2
<Source>
Selects the source for Analog Out 2.
Parameters:
<Source>
CH1_DDM | CH2_DDM | CH1_BB_FULL | CH2_BB_FULL |
CH1_BB_AUDIO | CH2_BB_AUDIO
Return values:
<State>
READY.
The command was executed successfully.
Common Instrument and Measurement Setup