Remote Commands
R&S
®
EVSG1000
378
User Manual 1178.6227.02 ─ 06
Remote commands exclusive to data streaming:
GETDATADEF
This command defines the data delivered by
GETDATASET
This command creates the output of the current streaming measurement results for the
active board.
Return values:
<ActBoard>
CH:1 | CH:2
The currently active receiver board for which the results are
returned.
<Data>
Data for the active board as described by
<State>
READY.
The command was executed successfully.
STREAM
<ParamSelection>, <RX Board>
Starts data streaming. In streaming mode, a measured data set is automatically send
to the remote interface. The Meastime (see
on page 245) defines how often
the data sets are produced. Every data set is preceded by the channel number.
Streaming can produce large quantities of output. It is mandatory to have a fast data
connection and an application that is able to handle the data.
Chapter 10.12.3, "Results for Data Streaming"
Parameters:
<ParamSelection>
ALL
All values of the current measurement are send as comma sep-
arated text, using current units.
FULL
Compatible to R&S EVS300.
MEDIUM
A fixed selection of parameters is exported.