Remote control commands
R&S
®
RTM3000
746
User Manual 1335.9090.02 ─ 09
POWer:SLEWrate:DTIMe
<DeltaTime>
Sets the delta time.
Parameters:
<DeltaTime>
POWer:SLEWrate:EXECute
Starts the slew rate measurement.
Usage:
Event
POWer:SLEWrate:REPort:ADD
Adds the result to the report list.
Usage:
Event
POWer:RIPPle:RESult:FREQuency[:ACTual]?
POWer:RIPPle:RESult:FREQuency:AVG?
POWer:RIPPle:RESult:FREQuency:NPEak?
POWer:RIPPle:RESult:FREQuency:PPEak?
POWer:RIPPle:RESult:FREQuency:STDDev?
POWer:RIPPle:RESult:FREQuency:WFMCount?
Returns the corresponding statistic result for the frequency.
●
[:ACTual]:
current measurement result
●
AVG:
average of the long-term measurement results
●
NPEak:
negative peak value of the long-term measurement results
●
PPEak:
positive peak value of the long-term measurement results
●
STDDev:
standard deviation of the long-term measurement results
●
WFMCount:
the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage:
Query only
POWer:SLEWrate:RESult:LPEak[:ACTual]?
POWer:SLEWrate:RESult:LPEak:AVG?
POWer:SLEWrate:RESult:LPEak:NPEak?
POWer:SLEWrate:RESult:LPEak:PPEak?
POWer:SLEWrate:RESult:LPEak:STDDev?
POWer:SLEWrate:RESult:LPEak:WFMCount?
Returns the corresponding statistic result for "Vp-".
●
[:ACTual]:
current measurement result
Power analysis (option R&S