LIN Trigger Settings
Figure 13-32: Trigger setup to trigger on identifier and data patterns
o (blue) = Selected bit in the 2
nd
byte of the data pattern, where the blue color indicates that the keypad is
active for this bit
............................................................................................ 304
LIN Trigger
Selects the trigger mode.
"Start of
Frame"
Triggers on the stop bit of the synchronization field.
"Wake Up"
Triggers after a wakeup frame.
"Error"
Identifies various errors in the frame. You can select one or more
error types as trigger condition.
See
"Identifier"
Sets the trigger to a specific message identifier or an identifier range.
Only the 6 bit identifier without parity bits is considered, not the pro-
tected identifier.
See
"Identifier and
Data"
Triggers on a combination of identifier and data condition. The instru-
ment triggers at the end of the last byte of the specified data pattern.
An example is shown in
See