
Remote control commands
R&S
®
RTM3000
594
User Manual 1335.9090.02 ─ 09
Setting parameters:
<MessageText>
String
String that contains the message.
Example:
DISP:DIAL:MESS 'My message'
DISP:DIAL:CLOS
Usage:
Setting only
DISPlay:GRID:STYLe
<Style>
Defines how the grid is displayed.
Parameters:
<Style>
LINes | RETicle | NONE
LINes
Displays the grid as horizontal and vertical lines.
RETicle
Displays crosshairs instead of a grid.
NONE
No grid is displayed.
*RST:
LIN
DISPlay:INTensity:GRID
<Intensity>
Defines the brightness of the grid lines in the diagram.
Parameters:
<Intensity>
Range:
0 to 100
Increment: 1
*RST:
not available, *RST does not change the intensity
Default unit: %
DISPlay:INTensity:WAVeform
<Intensity>
Defines the brightness of the waveform lines in the diagram.
Parameters:
<Intensity>
Range:
0 to 100
Increment: 1
*RST:
not available, *RST does not change the intensity
Default unit: %
DISPlay:PALette
<Palette>
Sets the color and brightness of the displayed waveform samples depending on their
cumulative occurance.
Parameters:
<Palette>
NORMal | INVerse
General instrument setup