ENGLISH
94
Picture 10 - Flue outlet on the side. Fixed connector for the flue outlet on the side.
2.10
ADJUSTABLE REAR FLUE OUTLET
(THERMAL COOKERS WITH OVEN)
On most models with oven it is possible to change
the position of the rear flue outlet. The move-
ment can be done both horizontally and vertical-
ly, in order to connect more easily the pipe to the
chimney hood. For the horizontal regulation, it is
necessary to unscrew the screws sustaining the
external sheet and then screw again them when
the flue outlet is in the chosen position. On some
models, it is possible to obtain further regulations
removing and tilting the sheet (see picture 12b).
On demand, Rizzoli can provide an extra sheet to
be used in the intermediate positions of the sheet.
For both the horizontal and the vertical regulations
there is a tolerance of 1 cm thanks to the provided
bayonet fitting as described in paragraph 2.9.
In the following tables are reported, for each mod-
el with oven, the minimum and maximum dimen-
sions (in mm) of the distances from the centre of
the hole of the rear flue outlet from the external
side of the frame.
The connection with the chimney must be always
well fixed and sealed, it must not have narrowing
and must not decrease the usable section of the
chimney (see picture 11). If near the thermal cook-
er there is inflammable material or high temper-
atures sensible, the connection must be isolated
and the safety distances must be strictly observed.
Picture 11 - Samples of correct and incorrect connection to the chimney hood.
NO
NO
NO
YES
Summary of Contents for RTE 60
Page 1: ...Istruzioni d uso Gebrauchsanweisung Instructions Manuel d utilisation...
Page 2: ......
Page 45: ...ITALIANO 43...
Page 87: ...DEUTSCH 85...
Page 129: ...ENGLISH 127...
Page 171: ...FRAN AIS 169...
Page 172: ...170...
Page 173: ...171...
Page 174: ...172...
Page 175: ......