14 TECHNICAL DATA
DESCRIPTION
UM
FAMILY
25 IS
35 IS
G20
G31
G20
G31
CH
Rated heat input
kW-kcal/h
20,00 (****)-17.200
32,00-27.520
Nominal heat output (80°/60°)
kW-kcal/h
19,50-16.770
31,23-26.860
Nominal heat output (50°/30°)
kW-kcal/h
21,32-18.335
34,37-29.556
Reduced heat input
kW-kcal/h
3,60-3.096
5,00-4.300
4,90-4.214
7,00-6.020
Reduced heat output (80°/60°)
kW-kcal/h
3,46-2,975
4,82-4.145
4,69-4.037
6,75-5.803
Reduced heat output (50°/30°)
kW-kcal/h
3,85-3.313
5,25-4.511
5,06-4.353
7,15-6.152
DHW
Rated heat input
kW-kcal/h
25,00 (****)-21.500
34,60-29.756
Nominal heat output (*)
kW-kcal/h
26,25-22.575
36,33-31.244
Reduced heat input
kW-kcal/h
3,60-3.096
5,00-4.300
4,90-4.214
7,00-6.020
Reduced heat output (*)
kW-kcal/h
3,28-2.821
5,00-4.300
4,54-3.904
7,00-6.020
Useful efficiency Pn max - Pn min (80°/60°)
%
97,5 - 96,1
97,6 - 95,8
Combustion efficiency
%
97,8
97,8
Useful efficiency Pn max - Pn min (50°/30°)
%
106,6 - 107,0
107,4 - 103,3
Useful efficiency 30% Pn max (30° return)
%
109,1
109,5
Overall electric output (maximum CH-DHW output)
W
88 - 98
101 - 112
Circulator electric power (1.000 l/h)
W
52
52
Category ● Country of destination
II2H3P
● (+)
II2HY203P
● (+)
II2H3P
● (+)
II2HY203P
● (+)
Voltage supply
V - Hz
230-50
230-50
Protection level
IP
X5D
X5D
Stop loss
W
30
26
Losses at the flue with burner off - burner on
%
0,09 - 2,20
0,05 - 2,23
Heating operation
Maximum pressure - temperature
bar - °C
3 - 90
3 - 90
Minimum pressure for standard operation
bar
0,25 ÷ 0,45
0,25 ÷ 0,45
Selection field of heating water temperature
°C
20/45 ÷ 40/80
20/45 ÷ 40/80
Pump: maximum head available
mbar
410
410
for system capacity
l/h
1.000
1.000
Membrane expansion tank
l
10
10
Expansion tank pre-loading (heating)
bar
1
1
Gas pressure
G20
G20.2
G31
G20
G20.2
G31
Nominal methane gas pressure (G20 - I2H)
mbar
20
-
-
20
-
-
Nominal methane-hydrogen gas pressure (G20.2 - I2Y20)
mbar
-
20
-
-
20
-
Nominal liquid gas LPG pressure (G31 - I3P)
mbar
-
-
37
-
-
37
Central heating capacity
Air capacity
Nm
3
/h
24,298
24,819
38,876
39,710
Flue gas capacity
Nm
3
/h
26,304
26,370
42,086
42,192
Mass flue gas flow rate (max-min)
g/s
9,086-1,635
9,297-2,324
14,537-2,226
14,875-3,254
Domestic hot water capacity
Air capacity
Nm
3
/h
30,372
31,024
42,035
42,937
Flue gas capacity
Nm
3
/h
32,880
32,963
45,506
45,620
Mass flue gas flow rate (max-min)
g/s
11,357-1,635
11,621-2,324
15,718-2,226
16,084-3,254
Fan performance
Residual discharge head of concentric pipes 0.85 m
Pa
60
60
Residual discharge head of separate pipes 0.5 m
Pa
174
190
Residual discharge head of boiler without pipes
Pa
180
195
NOx
class 6
class 6
Emission values at maximum and minimum output (**)
Max-Min
CO s.a. less than
p.p.m.
130-10
130-10
170-10
160-10
CO2 (***)
%
9,0-9,0
10,0-10,0
9,0-9,0
10,0-10,0
NOx s.a. lower than
p.p.m.
30-30
30-30
50-25
50-40
T flue gases
°C
69-63
68-62
64-65
67-63
(*) average value between various hot water operation conditions - (**) Check performed with concentric pipe Ø 60-100, length 0.85 m. - water temperature 80-60°C.- (***) tolerance CO2 +0.6% -1% -
(****) The rated heat input with gas G20.2 (I2Y20) undergoes a reduction: Rated heat input heating = 18,9kW; Rated heat input DHW = 23,1kW
The data indicated must not be used to certify the system; for certification, use the data indicated in the “System handbook” measured during first ignition.
(+) The installation of this product is allowed only in the destination Countries contained in the data plate, regardless of the present translation language.
b
DHW functions refer only if a water tank is connected (accessory available on request)