Move inside the display until the
icon is highlighted. The error message will be displayed.
The faults description screen is automatically displayed once the display illumination time
has elapsed without any button being pressed.
Reset function
To restore boiler operation, press “
ENTER
” from the error message screen. At this point,
if the correct operating conditions have been restored, the boiler will restart automatically.
There are a maximum of 3 consecutive attempts at a release by the REC10CH. In case of
all the attempts are exhausted the definitive fault E099 occurs on the display. The boiler will
need to be unlock by cutting off and reconnecting the electrical supply.
E020
RESET ATT. EXHAUSTED
LIMIT THERMOSTAT
b
If the reset attempts do not activate the boiler, contact the Technical Assistance
Centre.
For fault E041:
if the pressure drops below the safety threshold of 0.3 bar the boiler displays
the fault code “E041 - WATER TRANSDUCER FILL THE SYSTEM” for a transitional time
of 30 seconds during which it is possible to open the external filling tap until the pressure is
between 1 and 1.5 bar.
E041
FILL THE SYSTEM
WATER TRANSDUCER
b
If the drop in pressure is very frequent, contact the Technical Assistance Centre.
For fault E060:
the appearance of this error, on only heating models with water tank with
probe connected, prevents DHW operation.
For fault E091:
the boiler has an auto-diagnostic system which, based on the total number
of hours in certain operating conditions, can signal the need to clean the primary exchanger
(alarm code E091). Once the cleaning operation has been completed, reset to zero the total
hour meter with special kit supplied as an accessory following procedure indicated below:
-
select TECHNICAL
EXHAUST PROBE RESET
CONFIRM or BACK.
CONFIRM OR DELETE SELECTION
CONFIRM
CANCEL
THE PARAMETER WILL BE
CHANGED
RANGE RATED
CALIBRATION
WEATHER COMPENSATION
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
INSTALLER
TECHNICAL
Note:
The meter resetting procedure should be carried out after each in-depth cleaning of
the primary exchanger or if this latter is replaced.
The total hours can be verified in the following way: INFO menu
FLUE GAS PROBE
press “
ENTER
” to display the value of the flue gases probe meter
30
°C
.3
MENU
STATE
SET
INFO
HOT WATER TEMPERATURE
FRI
1.3
bar
18/05/2013
12:17
PLANT
Boiler faults list
ERROR CODE
ERROR MESSAGE
DESCRIPTION OF TYPE OF ALARM
E010
flame lockout/ACF electronic fault
definitive
E011
extraneous flame
transitional
E020
limit thermostat
definitive
E030
fan fault
definitive
E040
water transducer – fill the system
definitive
E041
water transducer – fill the system
transitional
E042
water pressure transducer fault
definitive
E060
water tank probe fault
transitional
E070
flow sensor faulty
flow sensor overtemperature
flow/return sensor differential alarm
transitional
definitive
definitive
E077
main zone water thermostat
transitional
E080
return line probe fault
return line probe overtemperature
outlet/return line probe differential alarm
transitional
definitive
definitive
E090
flue gas probe faulty
flue gas probe overtemperature
transitional
definitive
E091
clean primary heat exchanger
transitional
E099
reset attempts exhausted, boiler blocked
definitive, not resettable
--
water pressure low - check system
transitional
--
water pressure high - check system
transitional
--
boiler board communication lost
transitional
--
BUS 485 communication lost
transitional
List of combustion faults
ERROR CODE
ERROR MESSAGE
DESCRIPTION OF TYPE OF ALARM
E021
ACC monitor error
These are temporary alarms that if they occur several times in an hour they become definitive; the alarm E097 is displayed and is followed by
post-purging for 45 seconds at the fan's maximum speed.
It is always possible to release the alarm before the end of the post-purging.
E022
ACC monitor error
E023
ACC monitor error
E024
ACC monitor error
E067
ACC monitor error
E088
ACC monitor error
E097
ACC monitor error
E085
incomplete combustion
These are temporary alarms that if they occur several times in an hour they become definitive; the last error to occur is displayed and is
followed by a post-purging of 2 minutes at the fan's maximum speed. It is not possible to release the alarm before the end of the post-purging
unless the boiler's power supply is switched off.
E094
incomplete combustion
E095
incomplete combustion
E058
mains voltage fault
These are temporary faults that restrict the ignition cycle.
E065
current modulation alarm
E086
flue gases obstruction alarm
Temporary fault signalled during Pre-Purging. Post-Purging is maintained for 5 min at maximum fan speed.