SP Adjustments
SM 3-77
B286/B289
R
ep
la
cem
en
t
and
Adjus
tm
ent
Size
Orientation
A0 Lengthways
A
Sideways (Eng. 11”)
B
Sideways (Eng. 17”)
D Lengthways
(Eng.
34”)
E Lengthways
(Eng.
44”)
2. Measure the cuts and check them against the standards of this table.
Cut Length (mm)
Cut Tolerance (mm)
Less than 297
±3
420 to 1189
±5
to 2000
±6
=3000 ±11
to 4000
±14
3. If a measurement is not in the standard range of the “Cut Tolerance” in the table above,
adjust SP1920-1 to -238 for each roll, paper width, and paper type.
Step 12: Synchro Cut (Trailing Edge Registration)
The following SPs are necessary for this step:
!
SP4961-1 (Original Adjustment – Synchro Cut Adjustment 210 mm)
!
SP4961-2 (Original Adjustment – Synchro Cut Adjustment 1000 mm)
!
SP4961-3 (Original Adjustment – Original Length Display)
1. Prepare
two
originals
!
1 original 210 mm long (A4 LEF)
!
1 original 1000 mm long (measure and cut)
2. Go into the SP mode and do SP4961-1.
3. Touch “COPY Window” and copy the 210 mm sheet that you prepared in Step 1.
4. Touch “SP Mode” to go back to the SP mode.
Summary of Contents for B286
Page 1: ...B286 B289 SERVICE MANUAL 003165MIU...
Page 2: ......
Page 3: ...B286 B289 SERVICE MANUAL...
Page 4: ......
Page 5: ...B286 B289 SERVICE MANUAL 003165MIU...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 27: ......
Page 29: ......
Page 34: ......
Page 35: ...INSTALLATION...
Page 36: ......
Page 117: ...PREVENTIVE MAINTENANCE...
Page 118: ......
Page 127: ...REPLACEMENT AND ADJUSTMENT...
Page 128: ......
Page 186: ...Boards B286 B289 3 58 SM 9 Remove the shield cover A x12 10 Remove A MCU x4 x1 B IPU x4...
Page 198: ...Others B286 B289 3 70 SM 4 Remove the cooling fan D x 1 x 3...
Page 216: ......
Page 217: ...TROUBLESHOOTING...
Page 218: ......
Page 269: ...SERVICE TABLES...
Page 270: ......
Page 507: ...DETAILS...
Page 508: ......
Page 511: ...Overview SM 6 3 B286 B289 Details 6 1 2 MECHANICAL COMPONENT LAYOUT...
Page 526: ...Image Processing B286 B289 6 18 SM Text Mode...
Page 529: ...Image Processing SM 6 21 B286 B289 Details Patched Original Mode...
Page 530: ...Image Processing B286 B289 6 22 SM Generation Mode...
Page 552: ...Development B286 B289 6 44 SM Toner End Recovery Flow Chart...
Page 613: ...SPECIFICATIONS...
Page 614: ......