Fusing Unit
B286/B289 6-76
SM
1941-1
0 to 50
Plain
20
1942-1 to 5*
1
0 to 50
Plain
0
0
5
15 0
1943-1 to 5*
1
0 to 50
Plain
0
0
20
20 0
1944-1 to -5
0 to 50
Plain
0
0
10
5 0
1948-1 to 5
60 to 180
Plain
100
65
60
60 60
-6 to 10
60 to 180
Translucent
130
100
60
60
60
-11 to x15
60 to 180
Film
60
60
60
60
60
*
1
SP1942, SP1943, SP1944 do not operate if they are set to “0.”
Pressure Roller Temperature Feedback
The graph and descriptions below (Plain Paper, Mode 3 selected) show how the
temperature of the hot roller is controlled using the difference in the temperatures of the
center and end of the pressure roller.
The temperature readings are fed back by the pressure roller thermistors (one at the end
and one at the center of the pressure roller). These difference between these readings are
compared with the value set for SP1941 (Press FB Ctrl Switch by Temp Diff).
Difference between Center, End Temperatures
< SP1941 (20
o
C)
> SP1941 (20
o
C)
Hot Roller
Control Temp.
SP1931 to SP1935
(Black Line)
SP1942 to SP1944
(Blue Line)
Summary of Contents for B286
Page 1: ...B286 B289 SERVICE MANUAL 003165MIU...
Page 2: ......
Page 3: ...B286 B289 SERVICE MANUAL...
Page 4: ......
Page 5: ...B286 B289 SERVICE MANUAL 003165MIU...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 27: ......
Page 29: ......
Page 34: ......
Page 35: ...INSTALLATION...
Page 36: ......
Page 117: ...PREVENTIVE MAINTENANCE...
Page 118: ......
Page 127: ...REPLACEMENT AND ADJUSTMENT...
Page 128: ......
Page 186: ...Boards B286 B289 3 58 SM 9 Remove the shield cover A x12 10 Remove A MCU x4 x1 B IPU x4...
Page 198: ...Others B286 B289 3 70 SM 4 Remove the cooling fan D x 1 x 3...
Page 216: ......
Page 217: ...TROUBLESHOOTING...
Page 218: ......
Page 269: ...SERVICE TABLES...
Page 270: ......
Page 507: ...DETAILS...
Page 508: ......
Page 511: ...Overview SM 6 3 B286 B289 Details 6 1 2 MECHANICAL COMPONENT LAYOUT...
Page 526: ...Image Processing B286 B289 6 18 SM Text Mode...
Page 529: ...Image Processing SM 6 21 B286 B289 Details Patched Original Mode...
Page 530: ...Image Processing B286 B289 6 22 SM Generation Mode...
Page 552: ...Development B286 B289 6 44 SM Toner End Recovery Flow Chart...
Page 613: ...SPECIFICATIONS...
Page 614: ......