16
16
Faster Warm-up
To decrease warm-up time, a smaller number of steps is done
immediately after the machine power is turned on. These are
the steps.
z
Drum potential sensor calibration
z
Development bias adjustment
z
Grid voltage adjustment
z
Laser diode power adjustment
The number of steps is controlled by SP 3904.
The default is 0 (the minimum number of steps is done), and
the charge corona wire is not cleaned. The machine is ready
after 30 seconds.
Other settings of SP 3904
z
1: The charge corona wire is also cleaned. Warm-up time is 70
seconds
z
2: Full process control is done. The same as the B064. Warm-
up time is 240 seconds
Summary of Contents for B246 SERIES
Page 2: ...2 2 Basic Information about the B246 Series...
Page 8: ...8 8 What Options Does the Machine Have...
Page 25: ...25 25 Overview This section tells you what units the class will install...
Page 37: ...37 37 Installation Copier...
Page 53: ...53 53 Installation Options...
Page 68: ...68 68 Installation Printer Scanner and Options Service manual section 1 24...
Page 69: ...69 69 Install the Options Use the procedures in the service manual section 1 24...
Page 70: ...70 70 Updating the Firmware...
Page 76: ...76 76 Simplified Display Here is an example of the simplified display...
Page 231: ...231 231 Belt Contact Mechanism 2...
Page 241: ...241 241 B246 SERIES TRAINING COPIER ENGINE FUSING Fusing will be described in this section...