RVF 327, 327 S, 330, 330 S
ex no. 1200
Error search and repair
page 138 of 144
Version 1.5
Problem
Possible cause
repairs
Grease prob-
lem
Weight inco
n-
sistenc
y
Porous cross
cut
Ventilation
problem
Interruption
problem
Tips on the
chart end
Vacuum canal is
stuffed with filling
material
1 clean
adjusted non ten-
sion time too short
Chose longer non tension
time
Filling material too
warm
Cool
filling
material
Filing material in
the minus area too
cold.
1 Warm up processed filling
material
Specific weight too
inconsistent
3 Fill hopper full, change weight
in weight correction mask.
Standing time be-
tween cutting time
and filling of the
raw sausage is too
long.
4 Shorten standing time
Too hard cut up
filling material.
Cut filling material according
to instructions
Cut up filling mate-
rial too warm
Change cutting process
Air proportion too
great through dull
cutting knife.
Use sharp cutting knife
Chamber in the
conveyor too
small.
Enlarge chamber; use pump
rotor with less wings